Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Adv Sci (Weinh) ; 10(17): e2301002, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37083256

RESUMO

2D transition metal dichalcogenides (TMDs) have significant research interests in various novel applications due to their intriguing physicochemical properties. Notably, one of the 2D TMDs, SnS2 , has superior chemiresistive sensing properties, including a planar crystal structure, a large surface-to-volume ratio, and a low electronic noise. However, the long-term stability of SnS2 in humid conditions remains a critical shortcoming towards a significant degradation of sensitivity. Herein, it is demonstrated that the subsequent self-assembly of zeolite imidazolate framework (ZIF-8) can be achieved in situ growing on SnS2 nanoflakes as the homogeneous porous materials. ZIF-8 layer on SnS2 allows the selective diffusion of target gas species, while effectively preventing the SnS2 from severe oxidative degradation. Molecular modeling such as molecular dynamic simulation and DFT calculation, further supports the mechanism of sensing stability and selectivity. From the results, the in situ grown ZIF-8 porous membrane on 2D materials corroborates the generalizable strategy for durable and reliable high-performance electronic applications of 2D materials.

2.
Adv Sci (Weinh) ; 10(17): e2207722, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37075741

RESUMO

The energy crisis and global shift toward sustainability drive the need for sustainable technologies that utilize often-wasted forms of energy. A multipurpose lighting device with a simplistic design that does not need electricity sources or conversions can be one such futuristic device. This study investigates the novel concept of a powerless lighting device driven by stray magnetic fields induced by power infrastructure for obstruction warning light systems. The device consists of mechanoluminescence (ML) composites of a Kirigami-shaped polydimethylsiloxane (PDMS) elastomer, ZnS:Cu particles, and a magneto-mechano-vibration (MMV) cantilever beam. Finite element analysis and luminescence characterization of the Kirigami structured ML composites are discussed, including the stress-strain distribution map and comparisons between different Kirigami structures based on stretchability and ML characteristic trade-offs. By coupling a Kirigami-structured ML material and an MMV cantilever structure, a device that can generate visible light as luminescence from a magnetic field can be created. Significant factors that contribute to luminescence generation and intensity are identified and optimized. Furthermore, the feasibility of the device is demonstrated by placing it in a practical environment. This further proves the functionality of the device in harvesting weak magnetic fields into luminescence or light, without complicated electrical energy conversion steps.

3.
Adv Sci (Weinh) ; 10(3): e2205179, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36442861

RESUMO

An innovative autonomous resonance-tuning (ART) energy harvester is reported that utilizes adaptive clamping systems driven by intrinsic mechanical mechanisms without outsourcing additional energy. The adaptive clamping system modulates the natural frequency of the harvester's main beam (MB) by adjusting the clamping position of the MB. The pulling force induced by the resonance vibration of the tuning beam (TB) provides the driving force for operating the adaptive clamp. The ART mechanism is possible by matching the natural frequencies of the TB and clamped MB. Detailed evaluations are conducted on the optimization of the adaptive clamp tolerance and TB design to increase the pulling force. The energy harvester exhibits an ultrawide resonance bandwidth of over 30 Hz in the commonly accessible low vibration frequency range (<100 Hz) owing to the ART function. The practical feasibility is demonstrated by evaluating the ART performance under both frequency and acceleration-variant conditions and powering a location tracking sensor.

4.
Sensors (Basel) ; 21(5)2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33803466

RESUMO

The breath gas analysis through gas phase chemical analysis draws attention in terms of non-invasive and real time monitoring. The array-type sensors are one of the diagnostic methods with high sensitivity and selectivity towards the target gases. Herein, we presented a 2 × 4 sensor array with a micro-heater and ceramic chip. The device is designed in a small size for portability, including the internal eight-channel sensor array. In2O3 NRs and WO3 NRs manufactured through the E-beam evaporator's glancing angle method were used as sensing materials. Pt, Pd, and Au metal catalysts were decorated for each channel to enhance functionality. The sensor array was measured for the exhaled gas biomarkers CH3COCH3, NO2, and H2S to confirm the respiratory diagnostic performance. Through this operation, the theoretical detection limit was calculated as 1.48 ppb for CH3COCH3, 1.9 ppt for NO2, and 2.47 ppb for H2S. This excellent detection performance indicates that our sensor array detected the CH3COCH3, NO2, and H2S as biomarkers, applying to the breath gas analysis. Our results showed the high potential of the gas sensor array as a non-invasive diagnostic tool that enables real-time monitoring.


Assuntos
Gases , Nanotubos , Biomarcadores , Testes Respiratórios , Óxidos
5.
Proc Natl Acad Sci U S A ; 117(45): 27906-27915, 2020 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-33106394

RESUMO

Soft microfluidic systems that capture, store, and perform biomarker analysis of microliter volumes of sweat, in situ, as it emerges from the surface of the skin, represent an emerging class of wearable technology with powerful capabilities that complement those of traditional biophysical sensing devices. Recent work establishes applications in the real-time characterization of sweat dynamics and sweat chemistry in the context of sports performance and healthcare diagnostics. This paper presents a collection of advances in biochemical sensors and microfluidic designs that support multimodal operation in the monitoring of physiological signatures directly correlated to physical and mental stresses. These wireless, battery-free, skin-interfaced devices combine lateral flow immunoassays for cortisol, fluorometric assays for glucose and ascorbic acid (vitamin C), and digital tracking of skin galvanic responses. Systematic benchtop evaluations and field studies on human subjects highlight the key features of this platform for the continuous, noninvasive monitoring of biochemical and biophysical correlates of the stress state.


Assuntos
Técnicas Biossensoriais/instrumentação , Microfluídica/métodos , Suor/química , Espectroscopia Dielétrica/instrumentação , Espectroscopia Dielétrica/métodos , Impedância Elétrica , Desenho de Equipamento/instrumentação , Desenho de Equipamento/métodos , Fluorometria , Humanos , Imunoensaio , Dispositivos Lab-On-A-Chip , Pele/química , Dispositivos Eletrônicos Vestíveis
6.
Biosens Bioelectron ; 136: 106-111, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31048212

RESUMO

Numerous studies reported that psychological fatigue is one of the main reasons leading fatal road crashes. In order to quantify fatigue level of each subject, we measured a concentration of salivary cortisol from 4 subjects (20-40 years of age) using the Smart Fatigue Phone, which consists of a lateral flow immunosensor and a smartphone-linked fluorescence signal reader, during 50-min driving session. Since the salivary cortisol needs to be measured below 1 ng/mL to distinguish the subjects from awaken-drivers, we have employed the fluorescence detection module (Limit of detection: 0.1 ng/mL). To validate correlation between fatigue status and salivary cortisol concentration measured by the Smart Fatigue Phone, the electroencephalogram (EEG) signal was simultaneously obtained from the participants. As a result, alpha wave and concentration of cortisol over time was highly correlated, reflecting that quantification of salivary cortisol can be used for real-time monitoring of driver fatigue (p < 0.05). The Smart Fatigue Phone is expected to be a useful tool for drivers to recognize their fatigue status and subsequently to make a decision for driving a car. Thus, we assume that this fatigue detection system will consequently minimize road crashes by quantifying salivary cortisol in real time in the near future.


Assuntos
Condução de Veículo , Fadiga/diagnóstico , Hidrocortisona/análise , Saliva/química , Smartphone , Adulto , Técnicas Biossensoriais , Eletroencefalografia , Ensaio de Imunoadsorção Enzimática , Feminino , Fluorescência , Humanos , Masculino
7.
Biosens Bioelectron ; 130: 414-419, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30219701

RESUMO

The estimation of bloodstain age is an important factor in forensic analysis. Previously, we have reported a smartphone-based colorimetric system for age estimation of bloodstain, in which Whole blood and EDTA whole blood were dropped on 4 different materials (700 µL) and captured using a smartphone for 72 h. In order to enhance sensitivity and accuracy of the previous system, the current work is dedicated towards the application of pattern recognition and classification of bloodstain images based on a smartphone. Three detection methods (blood pool, crack ratio, and colorimetric analysis) in terms of 6 steps of drying process of the bloodstain (coagulation, gelation, edge desiccation, center desiccation, crack propagation, and final desiccation) were applied to estimate age of the bloodstain accurately. Three parameters from the bloodstain images were then classified as comparing to those of stored reference images with similar trends in database. The bloodstain age was successfully determined by 9 h, 18 h, and 48 h with respect to the three detection methods mentioned above, respectively. The differences in bloodstain images were clearly distinguished every hour by using smartphone-based pattern recognition analysis. Therefore, our system is expected to shed a light on the field of forensic science by estimating bloodstain age in real time.


Assuntos
Envelhecimento/sangue , Técnicas Biossensoriais , Manchas de Sangue , Smartphone , Colorimetria/métodos , Medicina Legal/métodos , Humanos , Fatores de Tempo
8.
Biosens Bioelectron ; 117: 385-391, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-29960270

RESUMO

Paper-based lateral-flow assay (LFA) is a simple and inexpensive point-of-care device that has become commonplace in medicine, environmental monitoring, and over-the-counter personal use. Some LFAs have demonstrated comparable analytical performance with laboratory-based methods, but the detection limit or sensitivity of most LFAs is significantly inferior to other molecular techniques by 10-100 × . Consequently, LFAs are not viable for the early detection of disease-relevant biomarkers that are present in extremely small amounts in clinical specimens. Herein, we present a simple, cost-effective, and highly sensitive LFA sensor based on photothermal laser speckle imaging (PT-LSI). Under the illumination of a photothermal excitation light, gold nanoparticles (AuNPs), a common signal transduction medium in LFAs, absorb the light energy to produce heat, which subsequently induces modulation of the optical property and thermal deformation of the membrane. We measured these fluctuations through laser speckle imaging to quantify the concentration of AuNP-biomarker complexes. We experimentally demonstrate that the detection limit of our technique is superior to that of colorimetric detector by 68-125 × . The capability of our sensor for highly sensitive detection of disease biomarkers is validated by using U.S. FDA-approved LFA kits for cryptococcal antigens (CrAg).


Assuntos
Técnicas Biossensoriais/instrumentação , Imunoensaio/instrumentação , Nanopartículas Metálicas/química , Antígenos de Bactérias/metabolismo , Cryptococcus/metabolismo , Ouro/química , Lasers , Limite de Detecção , Imagem Óptica
9.
Analyst ; 143(7): 1515-1525, 2018 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-29536992

RESUMO

The emergence of a wide range of applications of smartphones along with advances in 'liquid biopsy' has significantly propelled medical research particularly in the field of in vitro diagnostics (IVD). Herein, we have presented a detailed analysis of IVD, its associated critical concerns and probable solutions. It also demonstrates the transition in terms of analytes from minimally invasive (blood) to non-invasive (urine, saliva and sweat) and depicts how the different features of a smartphone can be integrated for specific diagnostic purposes. This review basically highlights recent advances in the applications of smartphone-based biosensors in IVD taking into account the following factors: accuracy and portability; quantitative and qualitative analysis; and centralization and decentralization tests. Furthermore, the critical concerns and future direction of diagnostics based on smartphones are also discussed.


Assuntos
Técnicas Biossensoriais , Técnicas e Procedimentos Diagnósticos , Smartphone , Humanos
10.
PLoS One ; 11(8): e0160557, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27552165

RESUMO

We investigated potential protein markers of post-mortem interval (PMI) using rat kidney and psoas muscle. Tissue samples were taken at 12 h intervals for up to 96 h after death by suffocation. Expression levels of eight soluble proteins were analyzed by Western blotting. Degradation patterns of selected proteins were clearly divided into three groups: short-term, mid-term, and long-term PMI markers based on the half maximum intensity of intact protein expression. In kidney, glycogen synthase (GS) and glycogen synthase kinase-3ß were degraded completely within 48 h making them short-term PMI markers. AMP-activated protein kinase α, caspase 3 and GS were short-term PMI markers in psoas muscle. Glyceraldehyde 3-phosphate dehydrogenase (GAPDH) was a mid-term PMI marker in both tissues. Expression levels of the typical long-term PMI markers, p53 and ß-catenin, were constant for at least 96 h post-mortem in both tissues. The degradation patterns of GS and caspase-3 were verified by immunohistochemistry in both tissues. GAPDH was chosen as a test PMI protein to perform a lateral flow assay (LFA). The presence of recombinant GAPDH was clearly detected in LFA and quantified in a concentration-dependent manner. These results suggest that LFA might be used to estimate PMI at a crime scene.


Assuntos
Rim/metabolismo , Mudanças Depois da Morte , Músculos Psoas/metabolismo , Animais , Autopsia , Patologia Legal , Expressão Gênica , Gliceraldeído 3-Fosfato Desidrogenase (NADP+)/metabolismo , Glicogênio Sintase/metabolismo , Humanos , Rim/patologia , Masculino , Músculos Psoas/patologia , Ratos , Proteína Supressora de Tumor p53/metabolismo , beta Catenina/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...